Technical characteristics

SPECIFICATION AND MAIN TECHNICAL PARAMETERS OF PC-SCC12 EVCC COMMUNICATION CONTROLLER
Specifications Model PC-SCC12

 

 

 

 

System configuration

CPU ARM cortex-M4
Memory 32M SDRAM ,256MnandFlash(options)
Operating system uC/OS
Interface(EVSE) CAN (Baud rate:115200):500K
RS-232/485 Baud rate:115200
PLC HomePlugGreenPHY1.1(HPGP1.1)
CP PWM detection (ADC); Voltage: ±12V(±5%)
Duty cycle:5%(±1%);Frequency: 1KHz(±1%)
Electrical characteristics Input voltage DC9~36V (recommended:12V)
Power consumption 3W
Working conditions Working temperature -25℃~60℃
Storage temperature -40℃~70℃
Mechanical dimensions Size 120mm*90mm*30mm
Weight 120g
EVCC satisfies the communication protocols of European standard DIN 70121 and American standard IEC/ISO-15118, which can be widely used for intelligent charging communication between electric vehicles and EVSE. The SECC developed and produced by our company can easily realize European standard and American standard DC charging. The PC-ECC12 is equipped with a complete V2G protocol stack, meeting the PLC (power line communication) communication requirements of HomePlug Green PHY 1.1 (HPGP 1.1) standard. At present, we have completed the DIN SPEC70121/12.14 communication certification of TUV, and have completed docking tests with various models around the world, helping many oems to complete customized development.


2. Features
  • Meet the requirements of automobile;
  • Meet the ac/dc charging communication requirements of PLC standard HPGP 1.1;
  • Meet DIN SPEC 70121:2014-12, ISO/IEC 15118-1/2/3 communication protocol;
  • Has completed DIN SPEC 70122:2018-11, ISO/IEC 15118-4/5 conformance
  • and interoperability tests, and obtained TUV certification.
  • CP and PD status monitoring function meeting IEC 61851-1;
  • EVCC has RS-232, RS-485, CAN BUS and other communication interfaces
  • to facilitate interactive communication with EVNET/BMS.
  • OTA remote upgrade or USB local upgrade.
  • Can customize the communication protocol between EVCC and vehicle in accordance with SAE J1939 format;
 

After-Sales support